TD-4520TN
FAQ & Fehlerbehebung |
TD-4520TN
Datum: 13.03.2019 Kennnummer: faqp00100466_000
How to calibrate the Gap/Black Mark Sensor by directly operating the printer
The Gap/Black Mark Sensor sensitivity should be calibrated whenever:
- A new printer is purchased
- Label stock is changed
- Printer initialization takes place
To calibrate the ribbon and Gap/Black Mark Sensor:
- Turn off the printer.
- Press and hold the Feed/Pause Button and then turn on the printer.
-
Release the button when the LED is flashing in red (5 times).
The LED color will change in the following order:
Amber > Red (5 times) (Release the button here) > Amber (5 times) > Green (5 times) > Green/Amber (blinks 5 times alternately) > Red/Amber (blinks 5 times alternately) > Green (lit)To select the sensor for calibration, send the correct command to the printer:
- For the Gap Sensor: the GAP command
- For the Black Mark Sensor: the BLINE command
You can also calibrate by using the BPM (Brother Printer Management Tool).
TD-4420TN, TD-4520TN
Wenn Sie weitere Unterstützung benötigen, wenden Sie sich an den Brother-Kundendienst:
Rückmeldung zum Inhalt
Helfen Sie uns dabei, unseren Support zu verbessern und geben Sie uns unten Ihre Rückmeldung.
Schritt 1: Wie hilfreich sind für Sie die Informationen auf dieser Seite?
Schritt 2: Möchten Sie noch ein paar Bemerkungen hinzufügen?
Bitte beachten Sie, dass dieses Formular nur für Rückmeldungen verwendet wird.