If you have print quality problems, clean the corona wires as follows:
1
Turn off the printer power switch. Press the front cover release button and then open the front cover.
2
Hold the green handle of the drum unit. Lift the drum unit up and then pull it out until it stops.
3
Hold the handle of the toner cartridge and pull it out of the drum unit. Repeat this for all the toner cartridges.
CAUTION
We recommend that you place the toner cartridge on a clean, flat surface with a piece of disposable paper underneath it in case you accidentally spill or scatter toner.
DO NOT put a toner cartridge into a fire. It could explode, resulting in injuries.
Handle the toner cartridge carefully. If toner scatters on your hands or clothes, wipe or wash it off with cold water at once.
To avoid print quality problems, DO NOT touch the shaded parts shown in the illustrations.
4
Push to release the latches of the white corona wire cover (1), and then open the cover.
Note
We recommend that you clean the corona wire for each of the colours. If you want to clean only the corona wire of the colour that caused the print quality problem, see the illustration below to identify the position of each of the corona wires.
1 Corona wire cover for Black (K)
2 Corona wire cover for Yellow (Y)
3 Corona wire cover for Magenta (M)
4 Corona wire cover for Cyan (C)
5
Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times.
CAUTION
Be sure to return the tab to the home position (1). If you do not, printed pages may have a vertical stripe.
6
Close the corona wire cover.
7
Repeat steps 4 to 6 to clean each of the remaining corona wires.
8
Hold the handle of the toner cartridge and slide the toner cartridge into the drum unit. Make sure that you match the toner cartridge colour to the same colour label on the drum unit, and make sure that you fold down the toner cartridge handle (1) once the toner cartridge is in place. Repeat this for all the toner cartridges.