If you have print quality problems, clean the corona wires as follows:
1 | Turn off the printer power switch. Fully open the top cover by lifting up on the handle (1). |
2 | Take out a drum unit and toner cartridge assembly.   IMPORTANT • | We recommend that you place the drum unit and toner cartridge assembly on a clean, flat surface with a sheet of disposable paper or cloth underneath it in case you accidentally spill or scatter toner. | • | To prevent damage to the printer from static electricity, DO NOT touch the electrodes shown in the illustration. |
|
3 | Clean the primary corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times.  Note | Be sure to return the tab to the home position (  ) (1). If you do not, printed pages may have a vertical stripe. |
|
4 | Slide the drum unit and toner cartridge assembly into the printer. Make sure that you match the toner cartridge colour to the same colour label on the printer. | | C - Cyan M - Magenta | Y - Yellow K - Black |
|
5 | Repeat steps 2 to 4 to clean each of the remaining corona wires. |
6 | Close the top cover of the printer. |