3 Control panel setup

LAN menu

Before using your Brother product in a network environment, you need to configure the correct TCP/IP settings. For more information, see Configuring your network printer.
In this chapter, you will learn how to configure the network settings using the control panel, located on the front of the machine.
The LAN menu selections of the control panel allow you to set up the Brother machine for your network configuration. Press Menu, then press Bsymbol.utri or Bsymbol.dtri to select LAN. Proceed to the menu selection you wish to configure. See Function table and default factory settings.
Please note that the machine is supplied with the BRAdmin Light Windows® software and Remote Setup applications for Windows® and Macintosh®, which also can be used to configure many aspects of the network. See Using the Remote Setup to change the print server settings(Not available for DCP models) for wired connection.

TCP/IP

This menu has nine sections: BOOT Method, IP Address, Subnet Mask, Gateway, Node Name, WINS Config, WINS Server, DNS Server and APIPA.

BOOT Method

This selection controls how the machine obtains the IP address for itself. The default setting is Auto.
Note Note
 
If you do not want your print server configured via DHCP, BOOTP or RARP, you must set the BOOT Method to Static so that the print server has a static IP address. This will prevent the print server from trying to obtain an IP address from any of these systems. To change the BOOT Method, use the machine’s control panel, BRAdmin Light utility or Remote Setup.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select BOOT Method.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Auto, Static, RARP, BOOTP or DHCP.
Press OK.
(For MFC-680CN) Press Bsymbol.ltri or Bsymbol.rtri to select Auto, Static, RARP, BOOTP or DHCP.
Press OK.
6
Press Stop/Exit.

IP Address

This field displays the current IP address of the machine. If you have selected a BOOT Method of Static, enter the IP address that you wish to assign to the machine (check with your network administrator for the IP address to use). If you have selected a method other than Static, the machine will attempt to determine its IP address using the DHCP or BOOTP protocols. The default IP address of your machine will probably be incompatible with the IP address numbering scheme of your network. We recommend that you contact your network administrator for an IP address for the network the unit will be connected on.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select IP Address.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 6.
6
Enter the IP address.
Press OK.
Note Note
 
For DCP models, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the IP address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the IP address. Press OK.
7
Press Stop/Exit.

Subnet Mask

This field displays the current subnet mask used by the machine. If you are not using DHCP or BOOTP to obtain the subnet mask, enter the desired subnet mask. Check with your network administrator for the subnet mask to use.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select Subnet Mask.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 6.
6
Enter the Subnet Mask address.
Press OK.
Note Note
 
For DCP models, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Subnet Mask. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Subnet Mask. Press OK.
7
Press Stop/Exit.

Gateway

This field displays the current gateway or router address used by the machine. If you are not using DHCP or BOOTP to obtain the gateway or router address, enter the address you wish to assign. If you do not have a gateway or router, leave this field blank. Check with your network administrator if you are unsure.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select Gateway.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 6.
6
Enter the Gateway address.
Press OK.
Note Note
 
For DCP models, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Gateway address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Gateway address. Press OK.
7
Press Stop/Exit.

Node Name

You can register the machine name on the Network. This name is often referred to as a NetBIOS name; it will be the name that is registered by the WINS server on your network. Brother recommends the name BRNxxxxxxxxxxxx for a wired network1 (where xxxxxxxxxxxx is your machine’s Ethernet address) (up to 15 characters).
1
For DCP-560CN, the default Node Name is BRN_xxxxxx (“xxxxxx” is the last six digits of Ethernet address).
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select Node Name.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 6.
6
Enter the Node Name.
Press OK.
Note Note
 
DCP models cannot change the Node Name from the control panel menu.
7
Press Stop/Exit.

WINS Config

This selection controls how the machine obtains the IP address of the WINS server.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select WINS Config.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Auto or Static.
Press OK.
(For MFC-680CN) Press Bsymbol.ltri or Bsymbol.rtri to select Auto or Static.
Press OK.
6
Press Stop/Exit.

WINS Server

1
Press Menu.
2
PressBsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select WINS Server.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Primary or Secondary.
Press OK.
6
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 7.
7
Enter the WINS Server address.
Press OK.
Note Note
 
For DCP models, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the WINS Server address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the WINS Server address. Press OK.
8
Press Stop/Exit.

DNS Server

1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select DNS Server.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select Primary or Secondary.
Press OK.
6
Press Bsymbol.utri or Bsymbol.dtri to select Change.
Press OK.
(For MFC-680CN) Skip to step 7.
7
Enter the DNS Server address.
Press OK.
Note Note
 
For DCP models, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the DNS Server address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the DNS Server address. Press OK.
8
Press Stop/Exit.

APIPA

The setting of On will cause the print server to automatically allocate a Link-Local IP address in the range (169.254.1.0 - 169.254.254.255) when the print server cannot obtain an IP address through the BOOT Method you have set (see BOOT Method). Selecting Off means the IP address doesn’t change, when the print server cannot obtain an IP address through the BOOT Method you have set.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to select LAN.
Press OK.
3
Press Bsymbol.utri or Bsymbol.dtri to select TCP/IP.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to select APIPA.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to select On or Off.
Press OK.
(For MFC-680CN) Press Bsymbol.ltri or Bsymbol.rtri to select On or Off.
Press OK.
6
Press Stop/Exit.