6 Control panel setup

Network menu

Before using your Brother product in a network environment, you need to configure the correct TCP/IP settings.
In this chapter, you will learn how to configure the network settings using the control panel, located on the front of the machine.
The Network menu selections of the control panel allow you to set up the Brother machine for your network configuration. Press Menu or MENU, then press Bsymbol.utri or Bsymbol.dtri to choose Network. Proceed to the menu selection you wish to configure. (See Function table and default factory settings.)
Please note that the machine is supplied with the BRAdmin Light software and Remote Setup applications for Windows® and Macintosh, which also can be used to configure many aspects of the network. (See Configuring your machine for a network with an Ethernet cable connection (Not available for MFC-253CW, MFC-255CW and MFC-257CW) for a wired connection or Changing the print server settings for a wireless connection.)

TCP/IP

If you connect the machine with the Ethernet cable to your network, use the Wired LAN menu selections. If you connect the machine to a wireless Ethernet network, use the WLAN menu selections. (Available for DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW, MFC-495CW and MFC-795CW)
This menu has 9 sections: BOOT Method, IP Address, Subnet Mask, Gateway, Node Name, WINS Config, WINS Server, DNS Server and APIPA.

BOOT Method

This selection controls how the machine obtains an IP address. The default setting is Auto.
Note Note
If you do not want your print server configured via DHCP, BOOTP or RARP, you must set the BOOT Method to Static so that the print server has a static IP address. This will prevent the print server from trying to obtain an IP address from any of these systems. To change the BOOT Method, use the machine’s control panel, BRAdmin Light utility or Remote Setup.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose BOOT Method.
Press OK.
6
(For DCP-365CN, DCP-373CW, DCP-375CW, DCP-377CW, MFC-253CW, MFC-255CW, MFC-257CW and MFC-295CN)
Press Bsymbol.utri or Bsymbol.dtri to choose Auto1, Static2, RARP3, BOOTP4 or DHCP5.
Press OK.
(For DCP-395CN, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW)
Press Bsymbol.ltri or Bsymbol.rtri to choose Auto1, Static2, RARP3, BOOTP4 or DHCP5.
Press OK.
7
Press Stop/Exit.
1
Auto mode
In this mode the machine will scan the network for a DHCP server. If it can find one, and if the DHCP server is configured to allocate an IP address to the machine, then the IP address supplied by the DHCP server will be used. If no DHCP server is available, then the machine will scan for a BOOTP server. If a BOOTP server is available, and it is configured correctly, the machine will take its IP address from the BOOTP server. If a BOOTP server is not available, the machine will scan for a RARP server. If a RARP server also does not answer, the IP Address is set using the APIPA protocol, see Using APIPA to configure the IP address. After the machine is initially powered ON, it may take a few minutes for the machine to scan the network for a server.
2
Static mode
In this mode the machine’s IP address must be manually assigned. Once entered the IP address is locked to the assigned address.
3
RARP mode
The Brother print server IP address can be configured using the Reverse ARP (RARP) service on your host computer. For more information on RARP, see Using RARP to configure the IP address.
4
BOOTP mode
BOOTP is an alternative to RARP that has the advantage of allowing configuration of the subnet mask and gateway. For more information on BOOTP, see Using BOOTP to configure the IP address.
5
DHCP mode (DHCP)
Dynamic Host Configuration Protocol (DHCP) is one of several automated mechanisms for IP address allocation. If you have a DHCP server in your network (typically a UNIX®, Windows® 2000/XP, Windows Vista® network) the print server will automatically obtain its IP address from a DHCP server and register its name with any RFC 1001 and 1002 compliant dynamic name services.

IP Address

This field displays the current IP address of the machine. If you have chosen a BOOT Method of Static, enter the IP address that you wish to assign to the machine (check with your network administrator for the IP address to use). If you have chosen a method other than Static, the machine will attempt to determine its IP address using the DHCP or BOOTP protocols. The default IP address of your machine will probably be incompatible with the IP address numbering scheme of your network. We recommend that you contact your network administrator for an IP address for the network the unit will be connected on.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose IP Address.
Press OK.
6
Enter the IP address.
Press OK.
Note Note
For DCP-365CN, DCP-373CW, DCP-375CW and DCP-377CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the IP address. Press OK to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the IP address. Press OK.
For DCP-395CN, DCP-593CW, DCP-595CW and DCP-597CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the IP address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the IP address. Press OK.
7
Press Stop/Exit.

Subnet Mask

This field displays the current subnet mask used by the machine. If you are not using DHCP or BOOTP to obtain the subnet mask, enter the desired subnet mask. Check with your network administrator for the subnet mask to use.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose Subnet Mask.
Press OK.
6
Enter the Subnet Mask address.
Press OK.
Note Note
For DCP-365CN, DCP-373CW, DCP-375CW and DCP-377CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Subnet Mask. Press OK to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Subnet Mask. Press OK.
For DCP-395CN, DCP-593CW, DCP-595CW and DCP-597CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Subnet Mask. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Subnet Mask. Press OK.
7
Press Stop/Exit.

Gateway

This field displays the current gateway or router address used by the machine. If you are not using DHCP or BOOTP to obtain the gateway or router address, enter the address you wish to assign. If you do not have a gateway or router, leave this field blank. Check with your network administrator if you are unsure.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose Gateway.
Press OK.
6
Enter the Gateway address.
Press OK.
Note Note
For DCP-365CN, DCP-373CW, DCP-375CW and DCP-377CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Gateway address. Press OK to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Gateway address. Press OK.
DCP-395CN, DCP-593CW, DCP-595CW and DCP-597CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the Gateway address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the Gateway address. Press OK.
7
Press Stop/Exit.

Node Name

You can register the machine name on the Network. This name is often referred to as a NetBIOS name; it will be the name that is registered by the WINS server on your network. Brother recommends the name BRNxxxxxxxxxxxx for a wired network or BRWxxxxxxxxxxxx for a wireless network (where xxxxxxxxxxxx is your machine’s Ethernet address) (up to 15 characters).
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose Node Name.
Press OK.
6
Enter the Node Name.
Press OK.
Note Note
DCP models cannot change the Node Name from the control panel menu. You can change the Node Name using BRAdmin Light or BRAdmin Professional 3.
7
Press Stop/Exit.

WINS Config

This selection controls how the machine obtains the IP address of the WINS server.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose WINS Config.
Press OK.
6
(For DCP-365CN, DCP-373CW, DCP-375CW, DCP-377CW, MFC-253CW, MFC-255CW, MFC-257CW and MFC-295CN)
Press Bsymbol.utri or Bsymbol.dtri to choose Auto or Static.
Press OK.
(For DCP-395CN, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW)
Press Bsymbol.ltri or Bsymbol.rtri to choose Auto or Static.
Press OK.
7
Press Stop/Exit.

WINS Server

1
Press Menu.
2
PressBsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose WINS Server.
Press OK.
6
Press Bsymbol.utri or Bsymbol.dtri to choose Primary or Secondary.
Press OK.
7
Enter the WINS Server address.
Press OK.
Note Note
For DCP-365CN, DCP-373CW, DCP-375CW and DCP-377CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the WINS Server address. Press OK to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the WINS Server address. Press OK.
DCP-395CN, DCP-593CW, DCP-595CW and DCP-597CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the WINS Server address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the WINS Server address. Press OK.
8
Press Stop/Exit.

DNS Server

1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose DNS Server.
Press OK.
6
Press Bsymbol.utri or Bsymbol.dtri to choose Primary or Secondary.
Press OK.
7
Enter the DNS Server address.
Press OK.
Note Note
For DCP-365CN, DCP-373CW, DCP-375CW and DCP-377CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the DNS Server address. Press OK to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the DNS Server address. Press OK.
DCP-395CN, DCP-593CW, DCP-595CW and DCP-597CW, press Bsymbol.utri or Bsymbol.dtri repeatedly to enter the first three-digit number for the DNS Server address. Press Bsymbol.rtri to enter the second three-digit number. Repeat this step until you have entered the fourth three-digit number to complete the DNS Server address. Press OK.
8
Press Stop/Exit.

APIPA

The setting of On will cause the print server to automatically allocate a Link-Local IP address in the range (169.254.1.0 - 169.254.254.255) when the print server cannot obtain an IP address through the BOOT Method you have set (see BOOT Method). Choosing Off means the IP address doesn’t change, when the print server cannot obtain an IP address through the BOOT Method you have set.
1
Press Menu.
2
Press Bsymbol.utri or Bsymbol.dtri to choose Network.
Press OK.
3
For DCP-373CW, DCP-375CW, DCP-377CW, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW
(For Wired) Press Bsymbol.utri or Bsymbol.dtri to choose Wired LAN.
(For Wireless) Press Bsymbol.utri or Bsymbol.dtri to choose WLAN.
Press OK.
4
Press Bsymbol.utri or Bsymbol.dtri to choose TCP/IP.
Press OK.
5
Press Bsymbol.utri or Bsymbol.dtri to choose APIPA.
Press OK.
6
(For DCP-365CN, DCP-373CW, DCP-375CW, DCP-377CW, MFC-253CW, MFC-255CW, MFC-257CW and MFC-295CN)
Press Bsymbol.utri or Bsymbol.dtri to choose On or Off.
Press OK.
(For DCP-395CN, DCP-593CW, DCP-595CW, DCP-597CW and MFC-495CW)
Press Bsymbol.ltri or Bsymbol.rtri to choose On or Off.
Press OK.
7
Press Stop/Exit.