Date: 27/01/2014 ID: faq00000208_000

How can I clean the corona wire of the drum unit?

If you are experiencing print quality problems, please clean the corona wire as follows:

 

Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.

 
  1. Turn off the printer power switch, and then unplug the printer power cord.

  2. Press the cover release button and then open the front cover of the printer.

  3. Take out the drum unit assembly (drum unit with the toner cartridge).

     

    • We recommend that you put the drum unit assembly on a piece of disposable paper or cloth in case you accidentally spill the toner.
    • To prevent damage to the printer from static electricity, do not touch the electrodes shown below.

     

     
  4. Clean the primary corona wire inside the drum unit by gently sliding the blue tab from right to left several times.

    Make sure to return the tab to the Home position. If you do not, printed pages will have a black vertical stripe.

     
  5. Put the drum unit assembly back in the printer.

  6. Close the front cover.

  7. Plug the printer power cord back in, and then turn the printer power switch back on.

 

Related Models

HL-6050D, HL-6050DN

If you need further assistance, please contact Brother customer service:

Content Feedback

To help us improve our support, please provide your feedback below.
Step 1: How does the information on this page help you?
Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.