DCP-9040CN
![]() |
Întrebări frecvente şi depanare |
![](/g/b/img/product/dcp9040cn_all.jpg)
DCP-9040CN
Dată: 10/05/2013 ID: faq00000211_014
White lines or bands or ribbing appear across the page.
![](/g/b/img/faqend/faq00000211_014/eu_ot/en/91853/27_pq_01.gif)
Please check the following points:
-
Make sure that the machine is on a solid level surface.
-
Make sure that the toner cartridges are installed properly.
Please refer to the instructions, "How do I replace the toner cartridge?". -
Shake the toner cartridges gently from side to side.
-
Make sure that the drum unit is installed properly.
Please refer to the instructions, "How do I replace the drum unit?". -
Make sure that you use paper that meets our specifications. A rough surfaced paper or thick print media can cause the problem.
Please refer to "What is the recommended paper?". -
Clean the laser scanner windows with a soft cloth.
Please refer to the instructions, "How do I clean the laser scanner windows?". -
The drum unit may be damaged. Put in a new drum unit.
Please refer to the instructions, "How do I replace the drum unit?".