DCP-7055W
![]() |
Ofte stillede spørgsmål og fejlfinding |
![](/g/b/img/product/dcp7055w_us_eu_as.jpg)
DCP-7055W
Dato: 04-02-2011 Id: faq00000701_008
White spots or black spots at 94 mm (3.7 in.) intervals
![Black spots](/g/b/img/faqend/faq00000701_008/eu_ot/en/26890/whiteorblackspots1.gif)
- Make ten copies of a blank, white sheet of paper.
If the problem is not solved, the drum unit may have glue from a label stuck on the OPC drum surface. Clean the drum unit. Please refer to the instructions, "Clean the drum unit".
- The drum unit may be damaged. Put in a new drum unit. Please refer to the instructions, "REPLACE DRUM"