Black lines down the page
Please check the following points:
-
(For models with Automatic Document Feeder only)
Wipe the scanner glass strip with a dry lint free soft cloth.
-
Clean the corona wire inside the drum unit by sliding the green tab.
> Click here to see how to clean the corona wire.
-
Make sure the green tab of the corona wire is at the home position.
-
The drum unit may be damaged. Put in a new drum unit.
> Click here to see how to replace the drum unit.
-
The toner cartridge may be damaged. Put in a new toner cartridge.
> Click here to see how to replace the toner cartridge.
- The fuser unit may be contaminated. Please contact Brother Customer Service from "Contact Us".