TJ-4422TN
![]() |
Nejčastější dotazy a pokyny pro odstraňování potíží |
![](/g/b/img/product/lptj4422tneuk.jpg)
TJ-4422TN
Datum: 28/09/2020 ID: faqp00100468_003
How to set the Gap/Black Mark Sensor as Media Sensor and calibrate the Gap/Black Mark Sensor by directly operating the printer
Follow the instructions below:
- Turn off the printer.
- Press and hold the right Selection button, and then turn on the Power Switch.
-
For the Black Mark Sensor
Release the button when Bline Calibration appears on the screen.
You can also release the button when the LED is flashing in green/amber (5 times).
The LED color will change in the following order:
Amber > red (5 times) > amber (5 times) > green (5 times) > green/amber (5 times) > red/amber (5 times) > green (lit)
For the Gap Sensor
Release the button when Gap Calibration appears on the screen.
You can also release the button when the LED is flashing in red/amber (5 times).
The LED color will change in the following order:
Amber > red (5 times) > amber (5 times) > green (5 times) > green/amber (5 times) > red/amber (5 times) > green (lit)You can also calibrate by using the BPM (Brother Printer Management Tool).