How to calibrate the RFID

For optimal calibration results, perform Media Calibration before RFID Calibration. Make sure you correctly install both the ribbon and the label roll.

 

  1. Perform Media Auto Calibration:

    Using the LCD menu:
    1. Load the RFID media into the printer.
    2. (Thermal transfer only) Load the ribbon into the printer.
    3. Press the Menu List icon (  ).
    4. Select the Sensor icon (  ).
    5. Select Auto Calibration > the media type > checkmark.
      Sensor - Auto Calibration
    Using the BPM (Brother Printer Management Tool):

    You can download the BPM from the [Downloads] section.

    1. Load the RFID media into the printer.
    2. (Thermal transfer only) Load the ribbon into the printer.
    3. Connect the USB cable between the computer and the printer.
    4. Start the BPM.
    5. Select the printer in the list, and then click the Printer Function button.
    6. Click Calibrate.
      Calibrate
    7. Click Printer Configuration and make sure that the paper width and height in the FBPL tab are set correctly.
    Using the AUTODETECT command:
    Send the AUTODETECT command using the BPM or Comm Tool.
    You can download the tools from the [Downloads] section

    For more information, see the FBPL Command Reference Manual in the [Manuals] section.

  2. Check that the RFID antenna is set at the center of the RFID chip or the antenna loop on the tag.
     
  3. Start RFID Calibration.

    Using the LCD Menu:
    1. Go to the RFID menu.
    2. Select Interface ) > RFID > Tag Calibration > Do RFID Calibrate > checkmark.
      LCD
    Using the RFIDDETECT command:
    Send the AUTODETECT command using the BPM or Comm Tool.
    You can download the tools from the [Downloads] section.

    For more information, see the FBPL Command Reference Manual in the [Manuals] section.

  4. When the calibration is complete, the green screen appears. When it is not successful, the red screen is displayed.
    Completed / RFID Calibrate

    Depending on the tag type and tag length, the calibration can take several minutes.

  5. If the calibration failed, press Back or Checkmark to clear the error. This can be mostly solved by repositioning the Antenna Slide.
    It also may be due to an incompatibility between the tag and the reader. After the calibration is complete, press Back or  to continue and save the RFID calibration values.

Relevante Modelle

TD-4650TNWBR, TD-4750TNWBR

Wenn Sie weitere Unterstützung benötigen, wenden Sie sich an den Brother-Kundendienst:

Rückmeldung zum Inhalt

Helfen Sie uns dabei, unseren Support zu verbessern und geben Sie uns unten Ihre Rückmeldung.
Schritt 1: Wie hilfreich sind für Sie die Informationen auf dieser Seite?
Schritt 2: Möchten Sie noch ein paar Bemerkungen hinzufügen?

Bitte beachten Sie, dass dieses Formular nur für Rückmeldungen verwendet wird.