CARTRIDGE ERROR

Make sure the drum unit and toner cartridge assembly is installed properly. 
If not, reinstall the drum unit and toner cartridge assembly to the machine as follows:

 

NOTE: Illustrations shown below are from representative product and may differ from your Brother machine.

 

  1. Open the front cover.
    Open the front cover
  2. Take out the drum unit and toner cartridge assembly.
    Take out the drum unit and toner cartridge assembly.
    • While removing the drum unit, handle it carefully because it may contain toner.
    • We recommend that you place the drum unit and/or the toner cartridge on a clean, flat, level, stable surface with a sheet of disposable paper or cloth underneath it in case you accidentally spill or scatter toner.
    • Handle the toner cartridge carefully. If toner scatters on your hands or clothes, immediately wipe or wash it off with cold water.
    • To prevent damage to the machine from static electricity, DO NOT touch the electrodes shown in the illustration.
      DO NOT touch
       
    • To avoid print quality problems, DO NOT touch the shaded parts shown in the illustrations.
      DO NOT touch

  3. Put the drum unit and toner cartridge assembly back into the machine again.

    Put the drum unit and toner cartridge assembly back into the machine again.
  4. Close the front cover.

Har du læst andre ofte stillede spørgsmål, hvis dit spørgsmål ikke blev besvaret?

Har du set i manualerne?

Kontakt Brother Support, hvis du har brug for yderligere hjælp:

Relaterede modeller

DCP-7055, DCP-7055W, DCP-7057, DCP-7060D, DCP-7065DN, DCP-7070DW, MFC-7360N, MFC-7460DN, MFC-7860DW

Feedback til indhold

Giv feedback herunder, så vi kan forbedre vores support.

Trin 1: Hvor hjælpsom har oplysningerne på denne side været?

Trin 2: Ønsker du at tilføje kommentarer?

Bemærk, at denne formular kun bruges til feedback.