RJ-3035B

Nejčastější dotazy a pokyny pro odstraňování potíží

Nejčastější dotazy a pokyny pro odstraňování potíží

How to calibrate the Gap/Black Mark Sensor by directly operating the printer

  • The Gap Sensor(*) / Black Mark Sensor sensitivity should be calibrated when:
     - A new printer is purchased
     - Label media is changed
    (*) Product specifications vary by region. For more information, see the Specification Sheet from the [Manuals] section of this website.
     
  • Models not equipped with the Black Mark Sensor cannot be used with Die Cut Labels.

To calibrate the Gap/Black Mark Sensor:
 

  1. Turn off the printer.
  2. Press and hold the Feed/Pause Button (  ) and then turn on the printer.
  3. Release the Feed/Pause button (  ) when the printer's Status LED changes to (  ) and starts blinking.


    The LEDs will change as follows:
    (Orange)
    (5 times)    -> Release the Feed/Pause button (  ) to enter calibration mode.
    (5 times)
    (5 times)
    (Green (lit))