Colored spots at 94 mm (3.7 in.) intervals or at 30 mm (1.2 in.) intervals
To solve the problem, follow the instructions below for your case:
Case 1: Colored spots at 94 mm (3.7 in.) intervals
Please check the following points to solve the problem:
- The drum unit or toner cartridges may not be installed correctly. Re-install the drum unit and toner cartridges.
- Print a few pages. If the problem is not solved, the drum may have foreign material, such as glue from a label, stuck on the drum surface. Clean the drum unit. Click here to see the details of how to clean the drum unit.
- The drum unit may be damaged. Put in a new drum unit. Click here to see the details of how to replace the drum unit.
Case 2: Colored spots at 30 mm (1.2 in.) intervals
Please check the following points to solve the problem:
- The drum unit or toner cartridges may not be installed correctly. Re-install the drum unit and toner cartridges.
- The toner cartridge may be damaged. Put in a new toner cartridge as follow:
- Click here to print the chart. [345KB/ PDF]
- Compare your printed document with the printed chart to identify the color causing the problem.
- Replace the toner cartridge of the color. Click here to see the details of how to replace the toner cartridge.
Wenn Ihre Frage nicht beantwortet werden konnte, haben Sie andere FAQ geprüft?
Haben Sie in den Handbüchern nachgesehen?
Wenn Sie weitere Unterstützung benötigen, wenden Sie sich an den Brother-Kundendienst:
Relevante Modelle
DCP-9055CDN, DCP-9270CDN, HL-4140CN, HL-4150CDN, HL-4570CDW, HL-4570CDWT, MFC-9460CDN, MFC-9465CDN, MFC-9970CDW
Rückmeldung zum Inhalt
Helfen Sie uns dabei, unseren Support zu verbessern und geben Sie uns unten Ihre Rückmeldung.