Date: 03/13/2013 ID: faq00002837_018

The Error LED is still on or flashing after I replace the drum unit with a new one.

The Error LED (Error) as shown below will continue to blink 3 times and turn off for 1second if the drum counter was not reset when you replace the drum unit with a new one.

DrumEndSoon

Drum End Soon / Replace Drum

To clear these LED indications, you need to reset the drum counter as instructed below.


If you want to clear an error LED related to the toner replacement, click here to see how to clear the LED indications after you replaced the toner cartridge.

 

Please follow the steps below to reset the drum counter.
NOTE: Illustrations shown below are from a representative product and may differ from your Brother machine.

 

The Brother machine has separate consumables the toner cartridge and the drum unit. Verify you replace only the drum unit and not the toner cartridge.


> Click here to see information for the difference between the toner cartridge and the drum unit.


Please reset the drum counter only when you replace the drum unit. If you reset the drum counter during the life of the drum unit currently being used, the remaining drum life will not be displayed accurately.

 

  1. Make sure that the machine is turned on.

  2. Open the top cover.

    OpenTopConver
  3. To reset the drum counter, press Power 4times.

    Press4times
  4. Close the top cover.

    CloseTopCover
  5. Make sure that the Error LED (Error) is now off.

Brother strongly recommends that customers use only genuine Brother drum units and/or toner cartridges Each Brother laser printer is designed to work at pre-set temperatures that are matched exactly to each of our individual toner formulations. Each individual component is designed to work with the other to ensure quality and reliability. Using non-Brother supplies may affect the hardware performance, print quality and machine reliability. The Brother limited warranty does not apply to any problem that is caused by the use of unauthorized third party drum units, toner cartridges or toner.


If the Error LED (Error) continue to blink 3 times and turn off for 1second, please contact Brother Customer Service from "Contact Us".

Related Models

HL-1110, HL-1112, HL-1200, HL-1202, HL-1212W

If you need further assistance, please contact Brother customer service:

Content Feedback

To help us improve our support, please provide your feedback below.
Step 1: How does the information on this page help you?
Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.