FAQs & Troubleshooting

Close

Model discontinued. This page is no longer updated.

HL-3450CN

FAQs & Troubleshooting

FAQs & Troubleshooting

HL-3450CN

Not your product?

Date: 01/29/2014 ID: faq00002293_000

How do I replace the Oil Bottle?

Follow the steps below to replace the Oil Bottle:

 

 

 

 

Before you start, make sure you turn OFF the printer and wait until it has cooled down sufficiently.

 

 
  1. Open the Top Cover.

     

  2. Release the Oil Bottle Lock Levers as shown:

     

  3. Remove the empty Oil Bottle from the Fusing Unit. Hold a sheet of paper under the Oil Bottle and lift it out of the Fusing Unit. Move the bottle away from the printer to the right so that the oil will not spill into it.

     

    Be careful not to spill oil inside the printer. It could cause considerable damage to the printer.

     
  4. Install the new Oil Bottle into the Fusing Unit with the label facing you. The Oil Bottle is keyed to prevent incorrect installation.

     

  5. Lock the Oil Bottle Lock Levers securely.

     

  6. Close the Top Cover.

     

  7. Press the Power button to turn the printer On.

     

 

Related Models

HL-3450CN

If you need further assistance, please contact Brother customer service:

Content Feedback

To help us improve our support, please provide your feedback below.
Step 1: How does the information on this page help you?
Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.