GS3700
FAQs & Troubleshooting |
GS3700
Date: 14/09/2017 ID: faqh00000095_006
How do I clean the machine? (Cleaning the race)
Sewing performance will suffer if dust collects in the bobbin case.
Therefore, it should be cleaned periodically.
Make sure you unplug the machine before you clean it, otherwise you risk getting an electric shock or being injured.
-
Turn off the machine and unplug it.
-
Raise the needle and the presser foot.
Mark on the handwheel
-
Loosen the presser foot screw and the needle clamp screw to remove the presser foot holder and the needle.
-
Using the oval screwdriver, remove the two screws. Lift up the needle plate as shown in the illustration, and then slide the needle plate to the left to remove it.
Use the oval screwdriver
-
Grasp the bobbin case, and then lift it out to the left.
-
Use the cleaning brush or a vacuum cleaner to remove any dust from the race and its surrounding area.
Cleaning brush Race
Do not apply oil to the bobbin case.
-
Insert the bobbin case so that the mark on the bobbin case aligns with the mark on machine as shown below.
mark mark
Align the and marks.
Bobbin case
Make sure that the indicated points are aligned before installing the bobbin case.
-
Install the needle plate, and then tighten the screws.
Screws
-
Never use a bobbin case that is scratched; otherwise the upper thread may become tangled, the needle may break, or sewing performance may suffer.
For a new bobbin case (part code: XE9326-001), contact your nearest authorized service center. - Make sure that you fit the bobbin case properly, otherwise the needle may break.
GS2500, GS2510, GS2520, GS2700, GS3700, GS3710
If you need further assistance, please contact Brother customer service:
Content Feedback