Date: 27/01/2014 ID: faq00000208_013

How can I clean the corona wire of the drum unit?

If you have print quality problems, clean the corona wire as follows:

 

Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.

 
  1. Press the front cover release button and then open the front cover.

  2. Take out the drum unit and toner cartridge assembly.

     

     

    • We recommend that you put the drum unit and toner cartridge assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
    • To prevent damage to the printer from static electricity, DO NOT touch the electrodes shown in the illustration.

     

     
  3. Clean the primary corona wire inside the drum unit by gently sliding the blue tab from right to left and left to right several times.

    Be sure to return the tab to the home position (1). If you do not, printed pages may have a vertical stripe.

     
  4. Put the drum unit and toner cartridge assembly back in the printer. Close the front cover.

 