HL-1430
常見問題&故障排除 |
HL-1430
日期:27.01.2014 ID:faq00000208_017
How do I clean the corona wire of the drum unit?
If you are experiencing print quality problems, please clean the corona wire as follows:
Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.
-
Unplug the printer.
-
Take the drum unit out of the printer.
We recommend that you place the Drum unit assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
- Carefully turn the drum unit upside down.
-
Clean the primary corona wire inside the drum unit by gently sliding the tab from right to left several times.
-
Return the tab to Home position before reinstalling the drum unit.
Be sure to return the tab to the Home position, or printed pages may have vertical stripes.
- Re-install the drum unit into the printer.
-
Close the front cover.
- Plug in the power cord.
如果您需要進一步的協助, 請聯絡Brother客戶服務:
內容意見回饋
請於下方回饋您的意見以幫助我們提升服務的品質