DCP-1610W
FAQs & Troubleshooting |
DCP-1610W
Date: 08/05/2013 ID: faq00000006_035
Black lines down the page
Check the following points:
-
Wipe the scanner glass strip with a dry lint free soft cloth.
Click here to see how to clean the scanner glass strip.
-
The corona wire of the drum unit may be dirty.
Click here to see how to clean the corona wires.
-
Make sure the green tab of the corona wire is at the home position.
-
The drum unit may be damaged. Put in a new drum unit.
Click here to see how to replace the drum unit.
-
The toner cartridge may be damaged. Put in a new toner cartridge.
DCP-1510, DCP-1512, DCP-1610W, DCP-1612W, MFC-1810, MFC-1910W