HL-1870N
FAQs & Troubleshooting |
HL-1870N
Date: 01/27/2014 ID: faq00000208_016
How do I clean the corona wire of the drum unit?
If you are experiencing print quality problems, please clean the corona wire as follows:
Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.
-
Press the Cover release button, and then open the Front cover.
-
Pull out the Drum unit assembly.
- We recommend that you place the Drum unit assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
- To prevent damage to the printer from static electricity, do not touch the electrodes shown below.
-
Clean the primary corona wire inside the Drum unit by gently sliding the blue tab from right to left several times. Return the tab to the Home position before re-installing the Drum unit assembly.
Be sure to position the tab to the Home position, or printed pages may have vertical stripes.
-
Re-install the Drum unit assembly into the printer.
-
Close the Front cover.
HL-1650, HL-1670N, HL-1850, HL-1870N
If you need further assistance, please contact Brother customer service:
Content Feedback
Please note this form is used for feedback only.