TD-4420TN

FAQs & Troubleshooting

FAQs & Troubleshooting

How to set the Gap/Black Mark Sensor as Media Sensor and calibrate the Gap/Black Mark Sensor by directly operating the printer

Follow the instructions below:

 

  1. Turn off the printer.

  2. Press and hold the Feed/Pause Button and then turn on the printer.

  3. For the Black Mark Sensor
    Release the button when the LED is lit in green/amber (blinks 5 times alternately) after the green LED flashes five times.
    The LED color will change in the following order:
    Amber > Red (5 times) > Amber (5 times) > Green (5 times) > Green/Amber (blinks 5 times alternately) (Release the button here) > Red/Amber (blinks 5 times alternately) > Green (lit)

    For the Gap Sensor
    Release the button when the LED is lit in red/amber (blinks 5 times alternately) after the green/amber LED flashes five times.
    The LED color will change in the following order:
    Amber > Red (5 times) > Amber (5 times) > Green (5 times) > Green/Amber (blinks 5 times alternately) > Red/Amber (blinks 5 times alternately) (Release the button here) > Green (lit)

    You can also calibrate by using the BPM (Brother Printer Management Tool).