Model discontinued. This page is no longer updated.

HL-1650

FAQs & Troubleshooting

FAQs & Troubleshooting

How do I clean the corona wire of the drum unit?

If you are experiencing print quality problems, please clean the corona wire as follows:

 

Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.

 
  1. Press the Cover release button, and then open the Front cover.

     

  2. Pull out the Drum unit assembly.

     

     

    • We recommend that you place the Drum unit assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
    • To prevent damage to the printer from static electricity, do not touch the electrodes shown below.

     

     
  3. Clean the primary corona wire inside the Drum unit by gently sliding the blue tab from right to left several times. Return the tab to the Home position before re-installing the Drum unit assembly.

     

    Be sure to position the tab to the Home position, or printed pages may have vertical stripes.

     
  4.  Re-install the Drum unit assembly into the printer.

     

  5. Close the Front cover.

     

 

If your question was not answered, have you checked other FAQs?

Have you checked the manuals?

If you need further assistance, please contact Brother customer service:

Related Models

HL-1650, HL-1670N, HL-1850, HL-1870N

Content Feedback

To help us improve our support, please provide your feedback below.

Step 1: How does the information on this page help you?

Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.