HL-L9200CDWT

FAQs & Troubleshooting

FAQs & Troubleshooting

Clean the corona wire

Follow the steps below to clean the corona wire.

 

  1. Make sure that the machine is turned on.
  2. Press the front cover release button and pull open the front cover.

     Open Front Cover
     
  3. Hold the blue handle of the drum unit. Pull the drum unit out until it stops.

     Pull Drum
     
  4. Hold the handle of the toner cartridge and gently push it toward the machine to unlock it. Then pull it out of the drum unit. Repeat this for all the toner cartridges.

     Pull Toner
     
  5. Clean the corona wire inside the drum unit by gently sliding the blue tab from left to right and right to left several times.
     
    Be sure to return the tab to the home position (1). If you do not, printed pages may have a vertical stripe.

     

    Clean Corona Wire
     
  6. Repeat step 5 to clean each of three remaining corona wires.
  7. Hold the handle of the toner cartridge and slide the toner cartridge into the drum unit then gently pull it toward you until you hear it click into place. Make sure that you match the toner cartridge color to the same color label on the drum unit. Repeat this for all the toner cartridges.

      Slide Toner
     
  8. Push the drum unit in until it stops.

      Push Drum
     
  9. Close the front cover of the machine.

If your question was not answered, have you checked other FAQs?

Have you checked the manuals?

If you need further assistance, please contact Brother customer service:

Related Models

HL-L8250CDN, HL-L8350CDW, HL-L8350CDWT, HL-L9200CDWT, HL-L9300CDW(T)

Content Feedback

To help us improve our support, please provide your feedback below.

Step 1: How does the information on this page help you?

Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.