Black lines down the page
Please check the following points to solve the problem:
-
(For models with Automatic Document Feeder only)
Wipe the scanner glass strip with a dry lint free soft cloth.
-
Clean the primary corona wire inside the drum unit by sliding the green tab.
Please refer to the instructions, "Clean the corona wire of the drum unit.".
-
Make sure the green tab of the primary corona wire is at the home position (
).
-
The drum unit may be damaged. Put in a new drum unit.
Please refer to the instructions, "REPLACE DRUM".
-
The toner cartridge may be damaged. Put in a new toner cartridge.
Please refer to the instructions, "REPLACE TONER".
- The fuser unit may be contaminated. Call your dealer or Brother Customer Service.