DCP-8155DN

FAQs & Troubleshooting

FAQs & Troubleshooting

Clean the corona wire

Please follow the steps below to clean the corona wire.

 

NOTE: Illustrations shown below are from a representative product and may differ from your Brother machine.

 

  • DO NOT use cleaning materials that contain ammonia, alcohol, any type of spray, or any type of flammable substance to clean the outside or inside of the machine. Doing this may cause a fire or electrical shock.

    DO NOT use flammable substances

  • Be careful not to inhale toner.

  1. Leave the machine turned on for 10 minutes for the internal fan to cool the extremely hot parts inside the machine.

  2. Press the front cover release button and then open the front cover.

    Open the front cover

  3. Take out the drum unit and toner cartridge assembly.

    Take out the drum unit and toner cartridge assembly

    • After you have just used the machine, some internal parts of the machine will be extremely hot. Wait for the machine to cool down before you touch the internal parts of the machine.

      Avoid touching the front side hot area

    • We recommend that you put the drum unit and toner cartridge assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
    • Handle the drum unit and toner cartridge assembly carefully. If toner scatters on your hands or clothes, immediately wipe or wash it off with cold water.
    • To prevent damage to the machine from static electricity, DO NOT touch the electrodes shown in the illustration.

      Avoid touching the electrodes
  1. Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times.

    Slide the green tab to clean the corona wire


    Be sure to return the tab to the home position (1). If you do not, printed pages may have a vertical stripe.

  2. Put the drum unit and toner cartridge assembly back into the machine.

    Put the drum unit and toner cartridge assembly back

  3. Close the front cover of the machine.

    If the "Drum Error" is displayed on the LCD after you cleaned the corona wire, the drum unit is near the end of its life. We recommend that you obtain a new drum unit to replace the current one. Click here to learn how to replace the drum unit.


     

If your question was not answered, have you checked other FAQs?

Have you checked the manuals?

If you need further assistance, please contact Brother customer service:

Related Models

DCP-8155DN, MFC-8510DN, MFC-8910DW

Content Feedback

To help us improve our support, please provide your feedback below.

Step 1: How does the information on this page help you?

Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.