Replace Pad
Your machine is equipped with a scan counter. The counter automatically counts how many times the machine has scanned. When the machine scans 10,000 times, the machine will display a message on the Status Monitor to remind you to replace the Separation Pad. Follow the steps below to replace the Separation Pad.
-
Open the Top Cover (1) and the Front Cover (2).
-
Slide the Separation Pad Holder up.
Be careful when touching the Separation Pad and its surrounding area in the machine. Otherwise, you could cause serious damage to the machine.
-
Pinch and pull the Separation Pad upward.
-
Attach a new Separation Pad.
-
Securely slide the Separation Pad Holder down.
-
Close the Front Cover and the Top Cover.
-
Reset the counter. Follow the steps below to reset the counter.
-
Press (Settings).
-
Press the Up or Down arrow key to display Machine Info..
-
Press Machine Info..
-
Press Usage Counters.
-
To reset the counter for the Separation Pad, press Separation Pad Count.
-
The LCD shows the confirmation message. Press Yes.
- Press .
-
Press (Settings).