How do I clean the machine? (Cleaning the race)
Sewing performance will suffer if dust collects in the bobbin case; therefore, it should be cleaned periodically.
Make sure you unplug the machine before you clean it.
Otherwise, you may get an electric shock or be injured.
-
Turn off the machine, and then unplug the power cord.
-
Remove the needle.
Refer to How do I change the needle?
-
Remove the presser foot and presser foot holder.
Refer to How do I remove or attach the presser foot? and How do I remove the presser foot holder?
-
Grasp both sides of the needle plate cover, and then slide it toward you to remove the needle plate cover.
(1) Needle plate cover -
Remove the bobbin case.
(1) Bobbin case * Grasp the bobbin case, and then pull it out.
-
Use the cleaning brush or a vacuum cleaner to remove any dust from the race and its surrounding area.
(1) Cleaning brush
(2) RaceDo not put oil on the bobbin case.
-
Insert the bobbin case so that the mark on the bobbin case aligns with the mark on the race.
(1) mark
(2) mark
(3) Bobbin case
* Align the and marks. Make sure that the indicated points are aligned before installing the bobbin case.
-
Never use a bobbin case that is scratched, otherwise the upper thread may become tangled, the needle may break or sewing performance may suffer.
For a new bobbin case (part code: XE7560-001), contact your nearest authorized service center. - Make sure that you fit the bobbin case properly, otherwise the needle may break.
-
Never use a bobbin case that is scratched, otherwise the upper thread may become tangled, the needle may break or sewing performance may suffer.
-
Put the tabs on the needle plate cover into the needle plate, and then slide the cover back on.
-
Install the presser foot holder and presser foot.
- Install the needle.