A different IP address is assigned every time the product is booted.

There may be router or server with DHCP or RARP functions enabled on your network. Check the DHCP server to see if the following solves the problem.

 

  1. Assign an IP address to the product in an environment without a router or server using only a HUB.
    Know the range of IP addresses that your DHCP server assigns.
    Be sure to assign an IP address for the product from the DHCP assignable range, but with the address in the same segment.
    Disable DHCP/BOOTP/RARP protocols.
    Example: In the case where the DHCP server assigns a range between 192.168.0.2 - 192.168.0.32, use any of the IP addresses between 192.168.0.33 - 192.168.0.253 for the product, such as 192.168.0.35.

    • Do not assign a duplicate IP address for another device.
    • It is recommended not to use 192.168.0.1 or 192.168.0.254, because the DHCP server may have this address.

  2. Register the IP address of the PS-9000 in the DHCP server
    Register the IP address of the product in the DHCP server.
    For detailed configuration, refer to the DHCP server manual.

Si vous n'avez pas obtenu de réponse satisfaisante à votre question, avez-vous vérifié d'autres FAQ?

Avez-vous consulté les manuels?

Pour toute assistance supplémentaire, contactez le service clientèle de Brother:

Modèles apparentés

PS-9000, PS-9000, PT-9200DX, PT-9500PC, QL-1050, QL-1050N, QL-500, QL-500A, QL-550, QL-560, QL-650TD

Commentaires sur le contenu

Merci d'indiquer vos commentaires ci-dessous. Ils nous aideront à améliorer notre support.

Étape 1: Comment qualifieriez-vous les informations figurant sur cette page?

Étape 2: Y a-t-il des commentaires que vous voudriez ajouter?

Ce formulaire a pour seul but de nous faire part de vos commentaires.