Model discontinued. This page is no longer updated.

HL-5250DN

FAQs & Troubleshooting

FAQs & Troubleshooting

How can I clean the corona wire of the drum unit?

If you have print quality problems, clean the corona wire as follows:

 

Do NOT use flammable substances or any type of spray to clean the inside or outside of the machine. Doing this may cause a fire or electrical shock.

 
  1. Press the front cover release button and then open the front cover.

  2. Take out the drum unit and toner cartridge assembly.

     

     

    • We recommend that you put the drum unit and toner cartridge assembly on a piece of disposable paper or cloth in case you accidentally spill or scatter toner.
    • To prevent damage to the printer from static electricity, DO NOT touch the electrodes shown in the illustration.

     

     
  3. Clean the primary corona wire inside the drum unit by gently sliding the blue tab from right to left and left to right several times.

    Be sure to return the tab to the home position (1). If you do not, printed pages may have a vertical stripe.

     
  4. Put the drum unit and toner cartridge assembly back in the printer. Close the front cover.

 

If your question was not answered, have you checked other FAQs?

Have you checked the manuals?

If you need further assistance, please contact Brother customer service:

Related Models

HL-5240, HL-5250DN, HL-5270DN

Content Feedback

To help us improve our support, please provide your feedback below.

Step 1: How does the information on this page help you?

Step 2: Are there any comments you would like to add?

Please note this form is used for feedback only.