DCP-7060D

FAQs & Troubleshooting

FAQs & Troubleshooting

All black

Print Quality Problem - ALL black

 

Please check the following points to solve the problem:

  • Clean the corona wire inside the drum unit by sliding the green tab. Be sure to return the green tab to the home position.
    Please refer to the instructions, "Clean the corona wire."

  • The drum unit may be damaged. Put in a new drum unit.
    Please refer to the instructions, "REPLACE DRUM".

  • The fuser unit may be contaminated. Call Brother Customer Service.

 

If your question was not answered, have you checked other FAQs?

Have you checked the manuals?

If you need further assistance, please contact Brother customer service:

Related Models

DCP-7055, DCP-7060D, DCP-7065DN, DCP-8110D, DCP-8155DN, FAX-2840, FAX-2950, HL-5440D, HL-5450DN, HL-5470DW, HL-6180DW, MFC-7240, MFC-7290, MFC-7360, MFC-7360N, MFC-7362N, MFC-7460DN, MFC-7470D, MFC-7860DN, MFC-7860DW, MFC-8510DN, MFC-8910DW, MFC-8950DW